Difference between revisions of "Extensions.DiagCom.IdentifyAndSelectVariant"

From emotive
Jump to navigation Jump to search
Line 14: Line 14:
 
{| {{TableHeader}}
 
{| {{TableHeader}}
 
{{TableRowPropertiesHeader}}
 
{{TableRowPropertiesHeader}}
{{TableRowPropertie1| Name | [[String]] | [[Value]] | - | [0..1] | Name to refer to the activity.}}
+
{{TableRowPropertie1| ComChannel | [[ComChannel]] | [[Variable]] | - | [1] | Communication Channel (Control unit).}}
{{TableRowPropertie2| Description | [[String]] | [[Value]] | - | - | Description (specification) of the activity.}}
 
{{TableRowPropertie1| Enabled | [[Boolean]] | [[Value]] | false | [0..1] | Activity is enabled or not.}}
 
{{TableRowPropertie2| ComChannel | [[ComChannel]] | [[Variable]] | - | [1] | Communication Channel (Control unit).}}
 
{{TableRowPropertie1| Valid for | [[Boolean]] | [[Term]] | - | [0..1] | Refers to a [[Validity]], which determines whether the activity at runtime is executed or not, see [[Validity]] concept.}}
 
 
|}
 
|}
  

Revision as of 10:22, 14 July 2014

Classification

Name IdentifyAndSelectVariant
Short Description Performs a variant identification by
Class Action
Extension OTX DiagCom extension
Group ComChanel related actions
Exceptions LossOfComException
Checker Rules -
Standard Compliant Yes

Pseudo-Code Syntax

IdentifyAndSelectVariant(ComChannel myComChannel);

Description

The OTX IdentifyAndSelectVariant activity is used to make the Diagnosis Runtime System to announce that it is the ECU variant is to select the appropriate communication channel, see Variant Identification . If an ECU variant can be determined, the current communication channel is switched to this variant.

Properties

Name Data Type Class Default Cardinality Description
ComChannel ComChannel Variable - [1] Communication Channel (Control unit).

Examples

ComChannel myComCannel = GetComChannel("LL_AirbaUDS", "", false);
IdentifyAndSelectVariant(ComChannel myComChannel);

See also

GetComChannel