Difference between revisions of "Extensions.DiagDataBrowsingPlus.GetParameterRadix"
Jump to navigation
Jump to search
(Created page with "{{DISPLAYTITLE:OTX '''GetParameterRadix'''}}Category:DiagDataBrowsingPlus == Classification == {{ClassificationActivity | GetParameterRadix| UPDATING... | Term | Ext...") |
|||
Line 1: | Line 1: | ||
{{DISPLAYTITLE:OTX '''GetParameterRadix'''}}[[Category:DiagDataBrowsingPlus]] | {{DISPLAYTITLE:OTX '''GetParameterRadix'''}}[[Category:DiagDataBrowsingPlus]] | ||
== Classification == | == Classification == | ||
− | {{ClassificationActivity | GetParameterRadix| | + | {{ClassificationActivity | GetParameterRadix| Gets the radix of the [[Extensions.DiagCom.Parameter|Parameter]] | [[Term]] | [[Extensions.DiagDataBrowsingPlus|OTX DiagDataBrowsingPlus extension]] | [[Extensions.DiagDataBrowsingPlus|Parameter related terms]] | [[Extensions.DiagDataBrowsingPlus.InvalidTypeException|InvalidTypeException]] | - }} |
== OTL Syntax == | == OTL Syntax == | ||
− | |||
<syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | <syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | ||
− | + | IntegerTerm = DiagDataBrowsingPlus.GetParameterRadix(ParameterTerm); | |
</syntaxhighlight> | </syntaxhighlight> | ||
− | |||
== Description == | == Description == | ||
− | + | '''GetParameterRadix''' returns the display radix of the [[Extensions.DiagCom.Parameter|parameter]]. The display radix shall be used by the Client to display a numeric parameter value in the format as defined in the data base (2 - ODX value BIN, 10 - ODX value DEC, 16 - ODX value HEX). | |
− | + | ||
− | {{ | + | If the [[Extensions.DiagCom.Parameter|parameter]] is not a A_UINT or A_INT value, the [[Extensions.DiagDataBrowsingPlus.InvalidTypeException|InvalidTypeException]] exception will be thrown. |
− | {{ | + | |
− | + | {{Note|NOTE — The appropriate MVCI system operation is Operation MCDParameter::getRadix}} | |
+ | |||
+ | {{Note|NOTE — This term is introduced to complete the existing terms in the [[Extensions.DiagDataBrowsing|DiagDataBrowsing extension]] (ISO 13209 Part-3 [3]) that uses ParameterTerms. This completion primarily enables a generically interpretation of responses by using runtime parameters without using [[Extensions.DiagDataBrowsingPlus.DbParameter|DbParameters]].}} | ||
+ | |||
+ | {{TermReturnValue| [[Core.DataTypes.SimpleDataType.Integer|Integer]] | Returns the display radix of the [[Extensions.DiagCom.Parameter|parameter]].}} | ||
== Properties == | == Properties == | ||
− | |||
{| {{TableHeader}} | {| {{TableHeader}} | ||
{{TableRowPropertiesHeader}} | {{TableRowPropertiesHeader}} | ||
− | {{ | + | {{TableRowPropertie2| parameter|[[Extensions.DiagCom.Parameter|Parameter]] | [[Term]] | - | [1..1] |The element addresses the '''Parameter''' (MCDParameter) which radix shall be returned.}} |
|} | |} | ||
− | |||
== OTL Examples == | == OTL Examples == | ||
− | |||
<syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | <syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | ||
− | DiagCom. | + | DiagCom.Result Result; |
+ | DiagCom.Response Response; | ||
+ | DiagCom.Parameter Parameter; | ||
+ | Integer MyInteger; | ||
− | + | /// Flow | |
− | / | + | [#MetaData(RequestPdu), <#Data>22 2A 19</#Data>] |
− | + | DiagCom.ExecuteDiagService(DiagCom.CreateDiagServiceByName(DiagCom.GetComChannel("LL_GatewUDS", "EV_GatewLear_006", false), "DiagnServi_ReadDataByIdentMeasuValue"), {Param_RecorDataIdent = "stall current measurement value"}, {}, Result, NULL, false, false); | |
− | DiagCom. | + | Response = DiagCom.GetFirstResponse(Result); |
+ | Parameter = DiagCom.GetParameterByPath(Response, {"Param_RespoServiId"}); | ||
+ | MyInteger = DiagDataBrowsingPlus.GetParameterRadix(Parameter); | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | |||
== See also == | == See also == | ||
− | + | [[Extensions.DiagCom.GetComChannel|GetComChannel]] <br/> | |
+ | [[Extensions.DiagCom.CreateDiagServiceByName|CreateDiagServiceByName]] <br/> | ||
+ | [[Extensions.DiagCom.CreateDiagServiceBySemantic|CreateDiagServiceBySemantic]] <br/> | ||
+ | [[Extensions.DiagCom.ExecuteDiagService|ExecuteDiagService]] <br/> | ||
+ | [[Extensions.DiagCom.GetFirstResponse|GetFirstResponse]] <br/> | ||
+ | [[Extensions.DiagCom.GetRequest|GetRequest]] <br/> | ||
+ | [[Extensions.DiagCom.GetParameterByPath|GetParameterByPath]] <br/> | ||
+ | [[Extensions.DiagCom.GetParameterBySemantic|GetParameterBySemantic]] <br/> |
Revision as of 07:03, 20 September 2018
Contents
Classification
Name | GetParameterRadix |
Short Description | Gets the radix of the Parameter |
Class | Term |
Extension | OTX DiagDataBrowsingPlus extension |
Group | Parameter related terms |
Exceptions | InvalidTypeException |
Checker Rules | - |
Standard Compliant | Yes |
OTL Syntax
IntegerTerm = DiagDataBrowsingPlus.GetParameterRadix(ParameterTerm);
Description
GetParameterRadix returns the display radix of the parameter. The display radix shall be used by the Client to display a numeric parameter value in the format as defined in the data base (2 - ODX value BIN, 10 - ODX value DEC, 16 - ODX value HEX).
If the parameter is not a A_UINT or A_INT value, the InvalidTypeException exception will be thrown.
![]()
NOTE — The appropriate MVCI system operation is Operation MCDParameter::getRadix
![]()
NOTE — This term is introduced to complete the existing terms in the DiagDataBrowsing extension (ISO 13209 Part-3 [3]) that uses ParameterTerms. This completion primarily enables a generically interpretation of responses by using runtime parameters without using DbParameters.
Return Value
The Term returns the value, see table below.
![]()
In OTX, Terms are categorized according to its return data type!
Data Type | Description |
Integer | Returns the display radix of the parameter. |
Properties
Name | Data Type | Class | Default | Cardinality | Description |
parameter | Parameter | Term | - | [1..1] | The element addresses the Parameter (MCDParameter) which radix shall be returned. |
OTL Examples
DiagCom.Result Result;
DiagCom.Response Response;
DiagCom.Parameter Parameter;
Integer MyInteger;
/// Flow
[#MetaData(RequestPdu), <#Data>22 2A 19</#Data>]
DiagCom.ExecuteDiagService(DiagCom.CreateDiagServiceByName(DiagCom.GetComChannel("LL_GatewUDS", "EV_GatewLear_006", false), "DiagnServi_ReadDataByIdentMeasuValue"), {Param_RecorDataIdent = "stall current measurement value"}, {}, Result, NULL, false, false);
Response = DiagCom.GetFirstResponse(Result);
Parameter = DiagCom.GetParameterByPath(Response, {"Param_RespoServiId"});
MyInteger = DiagDataBrowsingPlus.GetParameterRadix(Parameter);
See also
GetComChannel
CreateDiagServiceByName
CreateDiagServiceBySemantic
ExecuteDiagService
GetFirstResponse
GetRequest
GetParameterByPath
GetParameterBySemantic