Difference between revisions of "Extensions.DiagDataBrowsingPlus.GetParameterDisplayUnitAsString"
Jump to navigation
Jump to search
(Created page with "{{DISPLAYTITLE:OTX '''GetParameterDisplayUnitAsString'''}}Category:DiagDataBrowsingPlus == Classification == {{ClassificationActivity | GetParameterDisplayUnitAsString| UP...") |
|||
Line 1: | Line 1: | ||
{{DISPLAYTITLE:OTX '''GetParameterDisplayUnitAsString'''}}[[Category:DiagDataBrowsingPlus]] | {{DISPLAYTITLE:OTX '''GetParameterDisplayUnitAsString'''}}[[Category:DiagDataBrowsingPlus]] | ||
== Classification == | == Classification == | ||
− | {{ClassificationActivity | GetParameterDisplayUnitAsString| | + | {{ClassificationActivity | GetParameterDisplayUnitAsString| Gets the display unit of the [[Extensions.DiagCom.Parameter|Parameter]] | [[Term]] | [[Extensions.DiagDataBrowsingPlus|OTX DiagDataBrowsingPlus extension]] | [[Extensions.DiagDataBrowsingPlus|Parameter related terms]] | [[Extensions.DiagDataBrowsingPlus.InvalidTypeException|InvalidTypeException]] | - }} |
== OTL Syntax == | == OTL Syntax == | ||
− | |||
<syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | <syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | ||
− | + | StringTerm = DiagDataBrowsingPlus.GetParameterDisplayUnitAsString(ParameterTerm); | |
</syntaxhighlight> | </syntaxhighlight> | ||
− | |||
== Description == | == Description == | ||
− | + | '''GetParameterDisplayUnitAsString''' returns the display unit information of the [[Extensions.DiagCom.Parameter|diag:Parameter]] as a [[Core.DataTypes.SimpleDataType.String|string]]. If the [[Extensions.DiagCom.Parameter|parameter]] is not of [[Core.DataTypes.SimpleDataType|simple data type]] or does not contain any unit information an empty string is returned. The unit is only available for parameters with simple data types. | |
− | + | ||
− | {{ | + | If If the [[Extensions.DiagCom.Parameter|parameter]] is not of [[Core.DataTypes.SimpleDataType|simple data type]] A_UINT (8-64), A_INT (8-64), FLOAT (32,64), TEXTTABLE, BITFIELD, ASCIISTRING, UNICODE2STRING or BYTEFIELD, the [[Extensions.DiagDataBrowsingPlus.InvalidTypeException|InvalidTypeException]] exception will be thrown. |
− | {{ | + | |
− | + | {{Note|NOTE — The appropriate MVCI system operation is MCDParameter::getUnit}} | |
+ | |||
+ | {{Note|NOTE — This term is introduced to complete the existing terms in the [[Extensions.DiagDataBrowsing|DiagDataBrowsing extension]] (ISO 13209 Part-3 [3]) that uses ParameterTerms. This completion primarily enables a generically interpretation of responses by using runtime parameters without using [[Extensions.DiagDataBrowsingPlus.DbParameter|DbParameters]].}} | ||
+ | |||
+ | {{TermReturnValue| [[Core.DataTypes.SimpleDataType.String|String]] | Returns the display unit information of the [[Extensions.DiagCom.Parameter|diag:Parameter]].}} | ||
== Properties == | == Properties == | ||
− | |||
{| {{TableHeader}} | {| {{TableHeader}} | ||
{{TableRowPropertiesHeader}} | {{TableRowPropertiesHeader}} | ||
− | {{ | + | {{TableRowPropertie2| parameter|[[Extensions.DiagCom.Parameter|Parameter]] | [[Term]] | - | [1..1] |The element addresses the '''Parameter''' (MCDParameter) which display unit shall be returned.}} |
|} | |} | ||
− | |||
== OTL Examples == | == OTL Examples == | ||
− | |||
<syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | <syntaxhighlight lang="java" enclose="div" style="font-size: medium;"> | ||
− | DiagCom. | + | DiagCom.Result Result; |
− | + | DiagCom.Response Response; | |
− | + | DiagCom.Parameter Parameter; | |
+ | String MyString; | ||
+ | |||
+ | /// Flow | ||
− | / | + | [#MetaData(RequestPdu), <#Data>22 2A 19</#Data>] |
− | + | DiagCom.ExecuteDiagService(DiagCom.CreateDiagServiceByName(DiagCom.GetComChannel("LL_GatewUDS", "EV_GatewLear_006", false), "DiagnServi_ReadDataByIdentMeasuValue"), {Param_RecorDataIdent = "stall current measurement value"}, {}, Result, NULL, false, false); | |
− | DiagCom. | + | Response = DiagCom.GetFirstResponse(Result); |
+ | Parameter = DiagCom.GetParameterByPath(Response, {"Param_DataRecor", "Param_StallCurreMeasuValue", "Case_MeasuValue", "Param_Ruhes"}); | ||
+ | MyString = DiagDataBrowsingPlus.GetParameterDisplayUnitAsString(Parameter); | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | |||
== See also == | == See also == | ||
− | + | [[Extensions.DiagCom.GetComChannel|GetComChannel]] <br/> | |
+ | [[Extensions.DiagCom.CreateDiagServiceByName|CreateDiagServiceByName]] <br/> | ||
+ | [[Extensions.DiagCom.CreateDiagServiceBySemantic|CreateDiagServiceBySemantic]] <br/> | ||
+ | [[Extensions.DiagCom.ExecuteDiagService|ExecuteDiagService]] <br/> | ||
+ | [[Extensions.DiagCom.GetFirstResponse|GetFirstResponse]] <br/> | ||
+ | [[Extensions.DiagCom.GetRequest|GetRequest]] <br/> | ||
+ | [[Extensions.DiagCom.GetParameterByPath|GetParameterByPath]] <br/> | ||
+ | [[Extensions.DiagCom.GetParameterBySemantic|GetParameterBySemantic]] <br/> |
Revision as of 04:49, 20 September 2018
Contents
Classification
Name | GetParameterDisplayUnitAsString |
Short Description | Gets the display unit of the Parameter |
Class | Term |
Extension | OTX DiagDataBrowsingPlus extension |
Group | Parameter related terms |
Exceptions | InvalidTypeException |
Checker Rules | - |
Standard Compliant | Yes |
OTL Syntax
StringTerm = DiagDataBrowsingPlus.GetParameterDisplayUnitAsString(ParameterTerm);
Description
GetParameterDisplayUnitAsString returns the display unit information of the diag:Parameter as a string. If the parameter is not of simple data type or does not contain any unit information an empty string is returned. The unit is only available for parameters with simple data types.
If If the parameter is not of simple data type A_UINT (8-64), A_INT (8-64), FLOAT (32,64), TEXTTABLE, BITFIELD, ASCIISTRING, UNICODE2STRING or BYTEFIELD, the InvalidTypeException exception will be thrown.
![]()
NOTE — The appropriate MVCI system operation is MCDParameter::getUnit
![]()
NOTE — This term is introduced to complete the existing terms in the DiagDataBrowsing extension (ISO 13209 Part-3 [3]) that uses ParameterTerms. This completion primarily enables a generically interpretation of responses by using runtime parameters without using DbParameters.
Return Value
The Term returns the value, see table below.
![]()
In OTX, Terms are categorized according to its return data type!
Data Type | Description |
String | Returns the display unit information of the diag:Parameter. |
Properties
Name | Data Type | Class | Default | Cardinality | Description |
parameter | Parameter | Term | - | [1..1] | The element addresses the Parameter (MCDParameter) which display unit shall be returned. |
OTL Examples
DiagCom.Result Result;
DiagCom.Response Response;
DiagCom.Parameter Parameter;
String MyString;
/// Flow
[#MetaData(RequestPdu), <#Data>22 2A 19</#Data>]
DiagCom.ExecuteDiagService(DiagCom.CreateDiagServiceByName(DiagCom.GetComChannel("LL_GatewUDS", "EV_GatewLear_006", false), "DiagnServi_ReadDataByIdentMeasuValue"), {Param_RecorDataIdent = "stall current measurement value"}, {}, Result, NULL, false, false);
Response = DiagCom.GetFirstResponse(Result);
Parameter = DiagCom.GetParameterByPath(Response, {"Param_DataRecor", "Param_StallCurreMeasuValue", "Case_MeasuValue", "Param_Ruhes"});
MyString = DiagDataBrowsingPlus.GetParameterDisplayUnitAsString(Parameter);
See also
GetComChannel
CreateDiagServiceByName
CreateDiagServiceBySemantic
ExecuteDiagService
GetFirstResponse
GetRequest
GetParameterByPath
GetParameterBySemantic